Our philosophy: ‘Work with integrity, provide quality… Gain trust & loyalty”.

Kitchen Extract Cleaning

At DECA Environmental Services Ltd, we provide professional kitchen canopy and extract ductwork cleaning services to commercial premises throughout the UK, in accordance with BESA TR19® Grease guidance.

With over 25 years of industry experience, our qualified engineers deliver reliable, professional services to some of the UK's leading hospitality brands, including Merlin, Mitchells & Butlers, McDonald's, Burger King, Marston's and Dishoom.

We help businesses reduce grease-related fire risks, maintain ventilation hygiene and keep kitchen extract systems clean, safe and compliant.

Commercial Kitchen Ductwork Cleaning

We provide professional cleaning of commercial kitchen extract and ductwork systems in line with TR19 regulations, helping businesses maintain safe, hygienic, and compliant kitchen environments.

Over time, grease, fat, and cooking residue build up inside kitchen canopy systems, extract fans, and ductwork. This build-up is not always visible from the outside, but it can become a serious hazard if left untreated.

The main danger of grease accumulation is fire risk. Grease deposits inside ductwork are highly flammable, and in the event of a kitchen fire, flames can spread rapidly through the extract system and into other parts of the building. Regular ductwork cleaning helps reduce this risk significantly.

Steamy commercial kitchen with hanging utensils, stainless steel cookware, and a large wok station.

A thorough kitchen duct clean is also important for health and safety, insurance compliance, and system efficiency. Clean ductwork improves airflow, helps extraction systems perform properly, reduces unpleasant odours, and can extend the life of the equipment.

All cleaning is carried out to TR19 standards, ensuring the system is cleaned to recognised industry guidance and providing peace of mind that your kitchen extract system is being maintained correctly.

What Are TR19 Standards

TR19 is a set of UK industry standards published by the Building Engineering Services Association (BESA) for the cleanliness, inspection, maintenance, and verification of ventilation and extraction systems. It is widely used as the benchmark for demonstrating compliance with health, safety, fire-risk, and insurance requirements.

The two main TR19 standards are

1. TR19 – Air which covers general ventilation and HVAC ductwork in commercial and public buildings. Its primary focus is indoor air quality, system hygiene, occupant health, and energy efficiency. 

2. TR19 – Grease which is a standalone specification for commercial kitchen extraction systems. It focuses on reducing fire risk caused by grease accumulation. 

TR19 grease applies to:

  • Restaurants

  • Hotels

  • Care homes

  • Schools

  • Hospitals

  • Any commercial kitchen


Key Requirements

Grease measurement

  • Average grease deposits must remain below 200 microns.

  • Any reading above 500 microns requires immediate localised cleaning.

  • Post-clean grease levels should be below 50 microns.

System coverage

The entire extraction system must be inspected and maintained:

  • Canopies

  • Grease filters

  • Horizontal ductwork

  • Vertical risers

  • Fans and motors

  • Discharge outlets

  • Access panels and hatches

Chefs cooking over an open flame in a busy commercial kitchen

Cleaning frequencies

Typical inspection and cleaning intervals are:

Kitchen Usage Recommended Frequency
Heavy use (12+ hrs/day) Every 3 months
Moderate use Every 6 months
Light use Every 12 months

Grease levels can require more frequent cleaning regardless of schedule.

Chef in an apron cooking at a smoky restaurant grill

Is TR19 a Legal Requirement?

Strictly speaking, TR19 itself is not legislation. However, it is widely regarded as the recognised method of demonstrating compliance with UK laws and regulations including:

  • Health and Safety at Work etc. Act 1974

  • Workplace (Health, Safety and Welfare) Regulations 1992

  • Regulatory Reform (Fire Safety) Order 2005

  • COSHH Regulations 2002

  • Building Safety Act 2022

Failure to maintain ventilation systems can lead to enforcement action, insurance disputes, increased fire risk, and poor indoor air quality.


Typical Responsibilities for Building Owners and Facilities Managers

  1. Maintain clean and effective ventilation systems.

  2. Arrange periodic inspections.

  3. Ensure cleaning is carried out when contamination thresholds are exceeded.

  4. Keep auditable records and reports.

  5. Use competent, accredited contractors.

  6. Retain evidence for insurers, auditors, and regulators.

Legislation

Organisation within the sector is working to improve fire safety and support it with robust regulation. Indeed, insurance companies are taking more notice of this requirement and are stipulating PPM service within their criteria and guidance.

Currently, the service requirements are supported by;

The Regulatory Reform (Fire Safety) Order 2005 which sets out requirement for service and.

TR19® Grease Specification for Fire Risk Management of Grease Accumulation Within Kitchen Extraction Systems which provides guidance and the standard for carrying out service.

The Building Safety Act 2022 which is the driving force to stronger regulation within the sector.

Here at DECA UK we take fire safety seriously and feel we are part of the prevention process.  We carry out our works to the highest standards, always following the guidance and offering support to the regulation of the industry.

Service

DECA Environmental are here to help. Our Kitchen extract cleaning and ductwork maintenance services includes:

  • Full survey and reporting of you KES

  • Professional cleaning standards

  • Full system cleaning in line with TR19® Grease Specification

  • Bespoke Canopy only services

  • Riser Cleaning

  • Access door installation

  • Production of full schematics as requested

  • Ductwork Repairs/ replacement

  • Fan replacement and maintenance services

At the end of the service/clean you will be provided with a full clean report with before and after clean photos and a compliance certificate for your records.

Close-up of a dirty metal industrial cooling fan with multiple blades and a central hub.

Call us today, we offer competitive rates and a professional service for your requirements.

Before and after…